PLL Alignment
See Required test equipment
See Alignment Locations
SETTINGS | CONNECTION |
ADJUST
|
ADJUST FOR |
10.240
MHz PLL REFERENCE: RX Mode, AM, Freq. to 26.965MHz Band D Fine and coarse clarifier control to center detent. |
Connect Frequency counter to IC5 Pin 4. |
|
Check for 10.2400MHz ±200 Hz. If tolerance is beyond this, replace X1 (10.240MHz). |
VCO
BUFFER: RX Mode, AM, Freq. to 26.965MHz Band D Fine and coarse clarifier control to center detent. |
Connect scope to TP3 (top bare lead of R74) |
L18 |
Adjust for max. RF (0.80V p-p typical). |
Connect scope to L22 secondary (bare lead of L50 ). |
L22
|
Adjust for max. RF (2.0V p-p typical) | |
VCO: RX Mode, AM, Freq. to 26.965MHz Band D Fine and coarse clarifier control to center detent. |
Connect DC voltmeter to TP2 (top bare lead of R116) |
L17
|
Adjust
for 3.20 VDC ±0.1 Vdc. Recheck at 25.615MHz for approx 2.0V. and 28.305MHz for approx 6.0V. |
PLL
OFFSET OSCILLATOR: RX Mode, AM, Freq. to 26.965MHz Band D Fine and coarse clarifier control to center detent. Modes as indicated. |
Connect
Frequency Counter to TP3 (top bare lead of R74). |
L20 |
AM: Adjust for 16.2700MHz ±20 Hz. . |