Test equipment required:
|
|
|
|
Power Supply: 13,8 V |
Frequency Counter |
Dummy Load 50 ohm |
Oscilloscope |
DC VTVM |
|
|
|
Preparation
alignment:
|
|
Clarifier |
Mid. |
SQ GAIN |
Max. |
AF GAIN |
Max. |
RF GAIN |
Max. |
MIC GAIN |
Max. |
MOD, S/RF |
S/RF |
NB/ANL |
Off |
RF SSG |
Modulation: 30% AM 1000Hz |
Step |
Condition |
Adjustment |
Procedure |
1 |
MODE:
RX AM |
L17 |
Connect osciloscope on TP4. Adjust for maximum reading. |
2 |
MODE:
RX AM |
L18 |
Connect DC Voltmeter on TP2. Adjust to obtain 5,5Volt. |
3 |
MODE:
RX AM |
L19 |
Connect oscilloscope on TP3. Adjust for maximum reading. |
4 |
MODE:
RX AM |
L25 |
Connect Frequency Counter on TP3. Adjust to obtain 16.490MHz +/- 20Hz. |
5 |
MODE:
RX USB |
L26 |
Connect Frequency Counter on TP3. Adjust to obtain 16.4925MHz +/- 20Hz. |
6 |
MODE:
RX LSB |
L27 |
Connect Frequency Counter on TP3. Adjust to obtain 16.4875MHz +/- 20Hz. |
7 |
MODE:
TX LSB |
VR6 |
Connect Frequency Counter on TP3. Adjust to obtain 16.875MHz +/- 20Hz. |
8 |
MODE:
RX AM |
L22 |
Connect Frequency Counter on TP3. Adjust to obtain 16.040MHz +/- 20Hz. |
9 |
MODE:
RX USB |
L23 |
Connect Frequency Counter on TP3. Adjust to obtain 16.0425MHz +/- 20Hz. |
10 |
MODE:
RX LSB |
L24 |
Connect Frequency Counter on TP3. Adjust to obtain 16.0375MHz +/- 20Hz. |
11 |
MODE: RX LSB |
L30 |
Connect Frequency Counter on TP6. Adjust to obtain 16.6975MHz +/- 20Hz. |
12 |
MODE: RX USB |
L29 |
Connect Frequency Counter on TP6. Adjust to obtain 16.6925MHz +/- 20Hz. |
13 |
MODE: TX AM |
L28 |
Connect Frequency Counter on Base from TR43. Adjust to obtain 16.6950MHz +/- 20Hz. |
Test equipment required:
|
|
|
|
Power Supply: 13,8 V |
AF Signal Generator |
RF Dummy Load 50 ohm |
Oscilloscope |
RF Power Meter |
Frequency Counter |
|
|
Preparation
alignment:
|
|
Clarifier |
Mid. |
SQ GAIN |
Max. |
AF GAIN |
Max. |
RF GAIN |
Max. |
MIC GAIN |
Max. |
MOD, S/RF |
S/RF |
NB/ANL |
Off |
Step |
Condition |
Adjustment |
Procedure |
1 |
Mode: TX USB |
VR11 |
Disconnect PC834. Connect DC Current Meter on TP9(+) and TP8(-). Adjust for 50mA. |
2 |
Mode: TX USB |
VR9 |
Disconnect PC834. Connect DC Current Meter on TP9(+) and TP7(-). Adjust for 40mA. |
3 |
Mode: TX USB |
VR10 |
Disconnect PC834. Connect DC Current Meter on TP9(+) and TP7(-). Adjust for 80mA. |
4 |
Mode: TX USB |
L46 |
Set the core of L46 to the bottom, adjust VR12 to minimum. |
5 | Mode:
TX USB 27.185MHz S1 and S2 ON Modulation: 2,4kHz and 500Hz |
L45 L48 L49 | Adjust the cores to obtain max. deviation on RF VoltMeter. Repeat this operation with lower AF levelss on MIC input. |
6 |
Mode: TX USB |
L46 |
Adjut to obtain max deviation on RF Voltmeter. Adjust to obtain a mimimum power difference between Ch.40 HIGH and Ch.1 LOW |
7 |
Mode: TX AM |
L37 |
Adjust to obtain max deviation on S/RF Meter |
8 |
Mode: TX AM |
VR12 |
Adjust to obtain 32,4 Volt on RF VoltMeter |
9 |
Mode: TX USB |
VR7 |
Adjust to obtain minimum difference between USB and LSB |
10 |
Mode: TX AM |
VR13 |
Adjust to obtain 10 Watt on RF Power meter |
11 |
Mode: TX AM |
VR8 |
Set Switch on S/RF. Adjust to set the S-meter between the Red and Green field |
12 |
Mode: TX AM |
VR14 |
Adjust to obtain 90 % AM-Modulation on Oscilloscope. |
13 |
Mode: TX FM |
VR5 |
Adjust to obtain +/- 2 kHz deviation on DeviationMeter. |
14 |
Mode: TX AM |
VR15 |
Set switch on MOD, AF SignalGenerator to obtain 50% modulation. Adjust levels of AF Signal Generator to 16dB. Adjust VR15 to obtain 100% modulation on S-Meter. |
|
|
|
|
Test equipment required:
|
|
|
|
Power Supply: 13,8 V |
RF Signal Generator |
Dummy Load 8 ohm |
Oscilloscope |
AF VTVM |
|
|
|
Preparation
alignment:
|
|
Clarifier |
Mid. |
SQ GAIN |
Max. |
AF GAIN |
Max. |
RF GAIN |
Max. |
MIC GAIN |
Max. |
MOD, S/RF |
S/RF |
NB/ANL |
Off |
RF SSG |
Modulation: 30% AM 1000Hz |
Step |
Condition |
Adjustment |
Procedure |
1 |
Mode:
RX AM |
L8 |
Set RF SSG on 27.185MHz, 1kHz 30% AM-mod. Adjust L8 for maximum reading on oscilloscope. |
2 |
Same as STEP 1 |
L7 L9 L11 L12 L13 L52 L3 L4 L5 |
Adjust level of RF SSG to obtain 2V on AF VTVM then adjust coils for maximum reading on meter. |
3 |
Same as STEP 1 |
L8 |
Adjust to obtain minimum difference between Ch. 40 and Ch. 1 |
4 |
Same as STEP 1 |
VR1 |
Set the level of RF SSG to 100mV. Adjust VR1 for "5-9" reading on tranceiver meter. |
5 |
Same as STEP 1 |
VR4 |
Set SQ on max. Adjust level of RF SSG to 1000mV, adjust VR4 so that the radio signal will apper on tranceiver. Set SQ on minimum. |
6 |
Same
as STEP 1 |
L14 L15 |
Set RF SSG on 27.186MHz. Adjust coils to obtain maximum reading on oscilloscope. |
7 |
Same as STEP 1 |
VR2 |
Set level of RF SSG to 100uV. Adjust VR2 to obtain "S9" on transmitter meter. |
8 |
Same
as STEP 1 |
VR3 |
Set level of RF SSG to 1000mV. Adjust VR3 so that the audio signal will apper on tranceiver |
9 |
Same
as STEP 1 |
L1 L2 |
Set RF SSG on 27.185MHz, 0% Mod., 10uV Level. Connect oscilloscope on D2 and adjust the coils to obtain maximum deviation. |
10 |
Same as STEP 1 |
L6 |
Set RF SSG on 27.185MHz with 1 kHz deviation, 1000mV Level. Adjust L6 to obtain maximum. |